Límine Radiofrequency device 100W power

Record ANVISA 80212480015

• Power of 100W
• Multipolar Technology
• Control of high powered emission
• Simplified and intuitive Programming with touch screen technology
• RF remote activation through keys on applicators

Description Límine

Límine Radiofrequency device

 

The LÍMINE is a radiofrequency device with the highest technology for esthetic and dermatological treatments. It features Multifrequency system composed of three different frequencies. The Multipolar technology covers all regions of treatment in a safe, practical and effective way. The LÍMINE has differentiated presence and the selection of resources is completely intuitive, with employment of touch screen technology. It features a system that controls the emission of power, optimizing its use and ensuring safety and comfort for the client and the professional.

Accessories Included

• DVD Instruction manual
• Body Applicator
• Concentric Body Tip
• Bipolar Body Tip
• Tripolar Body Tip
• Hexapolar Body Tip
• Facial Applicator
• Concentrically Facial Tip
• Bipolar Facial Tip
• Tripolar Facial Tip
• Infrared Thermometer
• Glycerin Gel
• Power Cord

Protocols

TREATMENT SUGGESTION

Reduction of Measures Protocol

1) Sanitize the region of treatment with physical Exfoliating Gel, performing gentle circular massage.

2) Spray water and remove.

3) Select on the Límine the region of treatment.

4) Check the temperature of the region of treatment using infra-red thermometer before starting the application.

5) Apply the glycerin gel, which accompanies the Límine, homogeneously throughout the area of application.

6) Determine the time of maintenance of the temperature. It is recommended that the maintenance of the temperature is 3 to 5 minutes/area.

7) Select the frequency of treatment. It is recommended that the use of lower frequencies.

8) Press the Start button on the screen or in the applicator, and start the application. It should be done by quadrants and with constant movements for the distribution of energy to be homogenous throughout the duration of treatment.

9) Gradually increase the intensity as the perception of the patient, considering the therapeutic temperature desired.

10) Monitor the temperature using an infrared thermometer, increase or decrease the intensity until the reach of the therapeutic temperature.

11) Reaching a temperature of 40°C, engage the maintenance time of treatment through the Start/Timer button on the screen or on the applicator. This way, the programmed time will regress and at end, the device switches off automatically.

12) Finish by applying massage cream with active lipolytic actives, and perform stimulating massage.

Facial Rejuvenation Protocol

1) Sanitize the entire face with physical exfoliating soap making gentle circular massage.

2) Spray water and remove.

3) Tone with tonic lotion

4) Connect the Facial Applicator on Límine

5) Select on the Límine the region of Facial treatment.

6) Check the temperature of the region of treatment using the infrared thermometer before the beginning of the application.

7) Apply the glycerin gel, which accompanies the Límine, homogeneously throughout the area of application.

8) Determine the time of maintenance of the temperature. It is recommended to maintain the temperature of 5 minutes/area.

9) Select the frequency of treatment. It is recommended to use higher frequencies.

10) Press the Start button on the screen or in the applicator, and start the application. It should be done by regions and with constant movements so the distribution of energy is uniform for the entire duration of therapy.

11) Gradually increase the intensity as the perception of the patient, considering the therapeutic temperature desired.

12) Monitor the temperature using an infrared thermometer, increase or decrease the intensity until the reach of the therapeutic temperature.

13) Reaching a temperature of 41°C, engage the maintenance time of treatment through the Start/Timer button on the screen or on the applicator. This way, the programmed time will regress and at end, the device switches off automatically.

14) Apply a Blend with DMAE and revitalizing serum.

15) At the end of the treatment apply a layer of soothing mask and wait 15 minutes.

16) Remove the mask and finish with solar protection filter.

Frequent Questions

1. What is the frequency of the equipment?

The equipment have frequencies of 0,6MHz, 1,2MHz And 2,4MHz.

2. What tips accompany the equipment?

The product comes with 3 facial tips (bipolar, longitudinal, concentric bipolar and tripolar). And 4 body tips (bipolar, longitudinal, bipolar concentric, hexapolar and tripolar).

3. What is the output power for the body?

100W.

4. What is the output power for the face?

50W.

5. What is type of coupling?

It features resistive coupling.

6. What is the product used for application of radiofrequency?

Glycerin Gel.

7. Is there any restriction of the use of radiofrequency in relation to skin types?

No, all skin types can benefit from the use of radiofrequency.

8. Is the thermometer supplied with the equipment?

Yes, the heat generated by the application of radiofrequency should be monitored and controlled through the thermometer that comes with the equipment.

9. Is the treatment painful? Does it have side effects?

No, the treatment is painless and non-invasive. The procedure provides a sensation of intense heat and moderate erythema that is maintained for a few minutes.

10. How long does a session of treatment with radiofrequency lasts?

It depends on the size of the area to be treated. The procedure may take from a few minutes to an hour.

11. Can pregnant women apply or receive radiofrequency therapy?

No, pregnant women should not operate or stay close to the equipment.

12. How to realize the Hygienization of tips?

The tips should be rinsed with water and neutral soap. Do not use thinner, benzene or other strong solvents.

13. Can the Límine be used associated to other esthetic treatments?

Yes, the result of a treatment with the Límine will be boosted if associated to other equipment such as the Vibria, Beauty Dermo, Stimulus-R, Stimulus Face, among others.

14. What is the periodicity that the sessions can be performed?

There is not a consensus in the literature about the interval between sessions, and may vary according to the therapeutic objective and evaluation of the patient. There are reports in the literature indicating the range of 7 to 21 days between sessions.